Tuesday, February 22, 2011

PLATE ROLLING

For all inspector yang xpernah tengok macam mana plate rolling,aku attached satu gambar untuk korang semua....
Plate yang dalam process rolling..Shell course untuk aku punye project for Shell Refinery Company (SRC)..construction code ASME VIII Div.2..

aku attached gak fabrication of pressure vessel flowchart untuk bagi gambaran yang lebih jelas bagi korang semua..
PRESSURE VESSEL FLOWCHART FABRICATION

TECHNICAL CUM AUDITOR

TECHNICAL INSPECTOR CUM AUDITOR - CONSUMER TESTING SERVICES



Functional area: Inspections / Audit
SGS Business Lines: Consumer Testing Services (CTS)
Reporting to: Operations Manager


Primary Responsibilities

Effectively and competently perform inspection / audit or any related task assigned by the superior.

Specific responsibilities


  • To perform inspection and audit according to the instruction given by the superior
  • To ensure fully understand the requirement before perform the tasks
  • To ensure complete internal report submitted timely
  • To perform any other tasks as assigned by direct superior

Profile

  • Minimum diploma or degree in Electrical & Electronic from recognized university or college
  • Related experience will be an added advantage but fresh graduates are encourage to apply

Skills

  • Good interpersonal and communication skills
  • Able to work independently with minimum supervision
  • Willingness to travel

Additional information
Working location to be based in Kota Kemuning, Shah Alam


(SIAPA2 BERMINAT BOLEH LAYARI LAMAN WEB SGS MALAYSIA.MESEJ INI AKU AMIK DARI YAHOO GROUP YANG AKU JOIN)

ELECTRICAL INSPECTOR

Salam and greeting semua

I am looking for a suitable Electrical inspector to carry out inspection activities for MV Switchgears -

Project: PNG LNG EPC4
Order: EXXEP -001 ( This is one of the Item in this PO)

Manufacturer:
ABB Malaysia

Equipment:
MV SwitchGears

Location:-
ABB MALAYSIA SDN BHD ( MYMAS-P )
SUBANG JAYA,
LOT 608 JALAN SS13/1K
47500 SELANGOR DARUL EHSAN
MALAYSIA
Tel: +60 5628 4888

Delivery - April 2011 to Aug 2011

Scope:
Conduct some designated interim visits during assembly, FAT test,Punch list.
Witness Final for Area 41

Inspector Should Ideally Have:
1) Good experience in MV/LV switchgears or other experience with similar type of material.
2) Previous experience inspecting at ABB malaysia
3) Previous experience with CB&I / ABB Lummus or Exxonmobil for similar equipment.


Yang berminat dan qualify please contact me or zulkarnain

Sukran

Adnan
0139821405


(MESEJ INI AKU AMIK DARI YAHOO GROUP YANG AKU JOIN)

SELAMAT MENCUBA

FABRICATION PRESSURE VESSEL(MARKING & ROLLING)

Assalammualaikum....

Dah lama aku xupdate blog aku ni..busy sikit la...sikit je la...heheh..aku sambung balik cerita pasal fabrication of pressure vessel @ dandang xberapi ni..selepas material receiving to the shop & in house inspector dah accepted baru la kontraktor berkenaan marking dekat plate tersebut mengikut saiz pressure vessel.Complete je marking,then inspector akan wat inspection on marking before cutting...kat tmpat aku ni production supervisor akan wat Request For Inspection(RFI),then baru la inspector akan check seperti gambar kat bawah ni..
Gambar in house inspector,LR inspector & Client inspector buat inspection before cutting @ after marking.Selalunye kalau wat inspection sekali ngan 3rd party inspector @ client, in house inspector akan wat inspection dahulu la..

Kalau marking tu accepted in house inspector akan "endorsed" & baru la kontraktor akan cut mengikut ape yang diorang mark..Siap marking diorang akan prepare edge preparation as per approved construction drawing(AFC)..edge preparation kena ensure complete before rolling kalau x susah ooooo...
aku attached lagi gambar plate yang dah siap rolling...
Ni ha gambar shell course yang dah siap dari sekeping plate..siap je rolling then,Engineering Term we call it "Shell Course"..okay aku chow wat inspection dulu..aku sambung ape nak wat ngan shell course ni nanti ye..babai...=)